Consultor Eletrônico



Kbase P33048: Error 10391 using Fatham High Availablity - replication even though the databases have the same -n
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   17/07/2008
Status: Verified

SYMPTOM(s):

Error 10391 using Fathom High Availability - replication even though the databases have the same -n

The source and target database must be started with identical number of users. (10391)

FACT(s) (Environment):

Fathom Replication 1.0A
Fathom Replication 2.0A

CAUSE:

The -n, -Ma and -Mn were not the same for the source and target database.

The error message reports that the -n value for the source and target database must be the same. This is a little misleading as the -Mn and-Ma must also match.

FIX:

Configure the target database to use the same -n , -Ma and -Mn values as the source database.