Win 95 and Pathworks connection gives error 1998

If you have customers trying to get a connection from a pc running
Windows 95 over Pathworks for Windows 95, who are recieving the error

NETBIOS call to server <server> returns error 18. Retrying. (1998)
and/or
NETBIOS call to server <server> returns error 20. Retrying. (1998)

they need to contact their local Digital Service center and request
the file:
DECDNP.VXD version 1.0.31 (or higher)

The problem is due to Windows 95/Pathworks for Windows 95 being
written for 32 bit. What is happening is that they are sending the
padding characters at the end of the hex value generated when you
define the remote-adapter-names.
We cannot work with these as we use 16bit netbios calls.