Kbase P2969: When using Results, error 3307 happens during an upgrade
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

FACT(s) (Environment):

SCO UnixWare 7.1.1
Progress 9.1B
Progress 9.1C

SYMPTOM(s):

After upgrade Application Rebuild results in an error

<segment-name> has exceeded its limit of <segment-size> bytes, in <file-name> at line # <line-number>. (3307)

Text Segment has exceeded its limit of 63488 bytes, in qbf6.d at line #1723 (3307)

CAUSE:

Bug# 20010723-001

CAUSE:

When migrating from Progress 9.1B to Progress 9.1C where the application database contains a large number of tables and many of the field names in the tables are the same the generated source code will exceed the text segment limit

FIX:

Upgrade to Progress 9.1D