Consultor Eletrônico



Kbase P28722: Error 6087 occurs when trying to access WEBSPEED tab under Appbuilder
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   10/15/2008
Status: Verified

FACT(s) (Environment):

WebSpeed 3.1D

SYMPTOM(s):

Error occurs when trying to access WEBSPEED tab under Appbuilder

Specified ActiveX control is not registered or the .ocx file was moved from where it was registered.

Error occurred in procedure: control_load adeuib/_vwebcon.w (6087)

CHANGE:

Installed new license, WS Workshop, into existing WebSpeed installation 3.1D

CHANGE:

installed SP 9.1D06

CAUSE:

The exact cause is unknown at the time of this writing

FIX:

The OCX files must be registered manually. Follow these steps to register cihttp.ocx and comctl32.ocx:

1) Open a Command Prompt window.

2) Change to WINDOWS\SYSTEM or WINNT\SYSTEM32.

3) Execute the following commands:

regsvr32 %DLC%\bin\system\cihttp.ocx