Consultor Eletrônico



Kbase P27292: Error 9173 occurs when trying to connect to the AdminService, Start AdminService as local System acc
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/10/2008
Status: Verified

FACT(s) (Environment):

Progress 9.1D
WebSpeed 3.1D
Windows NT 32 Intel/Windows 2000

SYMPTOM(s):

Error 9173 when trying to connect to the AdminService on a Windows 2000 Active directory controller

Windows 2000 Active directory

No security enhancements / features were enabled within 9.1D

Unable to connect to AdminService when started under DOMAIN\Administrator

Unable to connect to AdminService when started under DOMAIN Administrator

Unable to connect to AdminService when started under DOMAIN\User

Unable to connect to AdminService when started under DOMAIN User

Invalid username and/or password specification. (9173)

"[TSE-ADC\]Administrator:Y:No Group Checking: User is not authenticated. (9897)" recorded in admserv.log

User is not authenticated. (9897)

Can not further increase priviledges of the user

CAUSE:

The root cause of the problem is a permissions issue - the user starting the AdminService does not have sufficient permission on OS level.

FIX:

Start the AdminService under LocalSystemAccount.