Kbase P25756: SYSTEM ERROR: Illegal instruction. (47) when starting up a d
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  5/23/2003 |
|
Status: Unverified
SYMPTOM(s):
SYSTEM ERROR: Illegal instruction. (47)
BROKER 0: SYSTEM ERROR: The broker is exiting unexpectedly, beginning Abnormal Shutdown. (5292)
Trying to start a database restored with prorest.
CAUSE:
Verify the backup file is good.
There may have been an error posted in the database log of the original database indicating an error during the probkup.
FIX:
Check that the media you are backing up to is not damaged.
Then try to backup the database again and restore from the newer backup.