Kbase P25621: Can't format message: NPUT phrase. Ignoring {0}. (5374 Args:
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  20/09/2003 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.1D
FACT(s) (Environment):
Windows NT 32 Intel/Windows 2000
SYMPTOM(s):
Errors when connecting from Progress Explorer to Admin Server
Can't format message: "NPUT phrase. Ignoring "{0}". (5374" Args: null
Can't format message: "NPUT phrase. Ignoring "{0}". (5374" Args: null
Exception: java.lang.NullPointerException
at java/text/MessageFormat.format
at java/text/MessageFormat.format
at java/text/Format.format
at java/text/MessageFormat.format
at com/progress/common/message/ProMessageFormat.format
at com/progress/common/message/ProMessageFormat.format
at com/progress/vj/util/ProMsgBox.getMsg
at com/progress/vj/util/ProMsgBox.error
at com/progress/vj/util/ProMsgBox.error
at com/progress/vj/explorer/ProgressServer.workingCallback2
at com/ms/lang/Delegate.dynamicInvoke0
at com/ms/lang/Delegate.dynamicInvoke
at com/ms/wfc/ui/Control.invokeMarshaledCallback
at com/ms/wfc/ui/Control.wndProc
at com/ms/wfc/ui/Form.wndProc
at com/ms/wfc/app/Application$ParkingForm.wndProc
at com/ms/wfc/ui/Control$ControlWindow.wndProc
at com/ms/wfc/app/Windows.callback
Progress 9.1B also present on the machine
CHANGE:
Installed 9.1D
CAUSE:
The environment variables DLC, PROMSGS still point to the older Progress version
FIX:
Check P5228 - Getting java errors when launching Progress Explorer in order to sort this problem out.