Kbase 15257: vmsshmmap failed on sys$mgblsc VMS error
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  10/05/1998 |
|
vmsshmmap failed on sys$mgblsc VMS error
vmsshmmap failed on sys$mgblsc
Occasionally, VMS users will get the above error. Things to
check for are any of the following SYSGEN parameters:
GBLPAGES
GBLPAGFILE
GBLSECTIONS <-- this is the most likely candidate. Try increasing.
Note:
Each PROGRESS qualifier /BUFFERS (-B) takes 2 global pages.
If the SYSGEN parameters are adequate, verify that the BIN:PROGRES.EXE
executable has the appropriate file protection.
DIR/FULL BIN:PROGRES.EXE
Directory PSC$BUILD:[RESD.RDL81A.ALPHA.DLC.BIN]
PROGRES.EXE;1 File ID: (8898,27,0)
Size: 8390/8398 Owner: [500,27]
Created: 18-AUG-1997 22:07:45.96
Revised: 18-AUG-1997 22:11:36.83 (2)
Expires: <None specified>
Backup: <No backup recorded>
Effective: <None specified>
Recording: <None specified>
File organization: Sequential
Shelved state: Online
File attributes: Allocation: 8398, Extend: 0, Global buffer cou
count: 0
Version limit: 5, Contiguous best try
Record format: Fixed length 512 byte records
Record attributes: None
RMS attributes: None
Journaling enabled: None
-> File protection: System:RWE, Owner:RWE, Group:RE, World:RE
Access Cntrl List: None
Total of 1 file, 8390/8398 blocks.
For additional information on how to modify DEC SYSGEN parameters and
file protection, please consult your VMS System Administration
Manual or contact DEC technical support for assistance.
Progress Software Technical Support Note # 15257