Kbase P23670: Truncating the BI results in error (762).
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  9/29/2003 |
|
Status: Unverified
FACT(s) (Environment):
IBM AIX
FACT(s) (Environment):
Progress 8.3D
SYMPTOM(s):
SYSTEM ERROR: bkaddr called with negative blkaddr: -1 (762)
Error (762) when truncating the BI.
Problem started after breaking a mirrored array of disks.
An IDXBUILD was performed without errors.
No hardware error messages appear in the UNIX log.
CAUSE:
Error (762) with a negative number happens when there is corruption in memory.
FIX:
Run hardware diagnostics, once the harware problem is fixed go to backups.