Kbase P23048: 'Update' button not enabled on ADM/2 update panel when migrating from 9.1B to 9.1D05.
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  12/31/2004 |
|
Status: Unverified
FACT(s) (Environment):
Windows
SYMPTOM(s):
UPDATE button not enabled on ADM/2 update panel when migrating from 9.1B to 9.1D05.
CAUSE:
The 9.1B smart update panel is a customized object. Since the smart update panel code changed considerably between 9.1B and 9.1D, the customized version did not work under 9.1D
FIX:
1. Start with a fresh copy of the 9.1D smart update panel 'pupdsav.w'.
2. Customize it as needed.
3. Replace the old 9.1B panel with the new 9.1D panel in the application window.