FACT(s) (Environment):

UNIX

FACT(s) (Environment):

Progress 8.3A

FACT(s) (Environment):

HP-UX 10.20

SYMPTOM(s):

Cannot start database after power cut

Starting the database via script: 'Server is already running'

Shutting down the database via script: 'There is no server for the database'

CAUSE:

Looks as though the ID of the shared memory segment in the master block from the time of the power cut is retained - when the an attempt is made to restart the database then Progress checks the segment and sees it is in use - hence the error message.

FIX:

Truncating the .bi appears to clear the shared memory segment from the master block