SYMPTOM(s):

I18N: Code page conversion table for iso8859-1 to ibm852 was not found in convmap.cp. (6063)

Code page conversion table for <table-name> to <table-name> was not found in <file-name>. (6063)

Client parameters are set to IBM852

Database is correctly configured for IBM852

$DLC/startup.pf is correctly configured for IBM852

Running specific r-code gives 6063 error

CAUSE:

There is no conversion table between iso8859-1 and ibm852. The r-code has been compiled using iso8859-1 codepage and this information is stored and used within the r-code.

FIX:

Recompile the source files using the IBM852 codepage