Kbase P20730: Error 6496 During Database Startup
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  21/08/2003 |
|
Status: Unverified
FACT(s) (Environment):
Progress 9.1C
FACT(s) (Environment):
Progress 9.1B
SYMPTOM(s):
Errors starting database.
** Save file named core for analysis by Progress Software Corporation. (439)
SYSTEM ERROR: Releasing regular latch. latchId:<latch-num> (5028)
SYSTEM ERROR: The broker is exiting unexpectedly, beginning Abnormal Shutdown. (5292)
SYSTEM ERROR: stgetbk: requested length greater than the shm segment (6496)
The errors seems to be database (or AI) dependent because it is not reproducible at will with a small test environment.
In most situations, it will happen only with large databases (greater than 1GB).
CHANGE:
AI (After Imaging) applied to a Progress database.
FIX:
A fix for this problem was incorporated in the latest patches for Progress 9.1B and 9.1C. To find and download the latest patch, go to the Technical Support section of the Progress Website.