Consultor Eletrônico



Kbase P19793: Running SmartContainer is AppBuilder gets error 290
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/10/2008
Status: Verified

FACT(s) (Environment):

Windows
Progress 9.1D

SYMPTOM(s):

SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290)

SYSTEM ERROR: I/O error 2 in readit, ret 0, file 22, addr 0. (290)

Trying to run a SmartObject container in the AppBuilder

Same SmartObject container works when run from the Procedure Editor

CAUSE:

A corrupted, non-existing or wrong .r file may generate this error

FIX:

Verify that the PROPATH points to the correct .r versions of all the application components and/or recompile all these components