Kbase P19419: Problem connecting to the appserver via weblient application
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  1/2/2009 |
|
Status: Verified
SYMPTOM(s):
Application server connect failure. (5468)
FSM ERROR: INVALID ACTION state= 1 event = 11 : FSM : action= 18 nextstate = 11
FATAL ERROR : (2) Protocol Error. (8121)
Ending serverPool thread: S-0006. (8077)
Adapter protocol error: Connection failure for host <hostname> port <port> transport <transport_name> (9407)
Both products are at service pack one level.
Ran test connect program and it failed to connect to the AppServer.
FACT(s) (Environment):
Windows 2000
Progress 9.1D
CAUSE:
The case of the AppService was not consistent.
FIX:
Change the case of the AppService to be consistent with what the application is asking for.