Kbase P19297: Error 5639 when using Dynamics over the Web interface.
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  18/03/2003 |
|
Status: Unverified
FACT(s) (Environment):
Dynamics 2.0A
SYMPTOM(s):
Error 5639 when using Dynamics over the Web interface.
User-defined function 'getPageSource' invoked dynamically but could not be found. (5639)
** ERROR: Could not get valid handle for SDO: benutzerfullo (adm2/dynsdo.w).
Program:getSDOHandle D:\Programme\Dynamics\tty\icf\ry\app\ryuimsrvrp.r
*** Error: PSC-5639
CAUSE:
There are several possible causes for this:
1. The Webspeed broker is not connecting to the application database.
2. The SDO logic procedure is not in the Webspeed broker propath.
3. Product modules have been created incorrectly so the logic procedure cannot be found
FIX:
1. Ensure the icfconfig.xml file connects all required databases for the Webspeed session.
2. Check the Webspeed broker propath.
3. Check the product modules have been created as expected. Note, in version 2.0A the Object Generator will create product module directories if they do not already exist.