SYMPTOM(s):
Database crashes with 290 error SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290) when drive controller is faulty.
SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290)
SYSTEM ERROR: I/O error 0 in readfrmb, ret 0 file (srt), addr <n>. (290)
SYSTEM ERROR: I/O error 22 in readit, ret -1, file <n>, addr 0. (290)
Progress Client reading information in from a sort file is getting error 290 SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290) when drive controller is faulty.
System log shows disk errors
FACT(s) (Environment):
UNIX
Progress/OpenEdge Product Family
CAUSE:
Not a Progress issue.
The problem can be caused by a disk or controller failure / error at the time a block is being read in the sort process.
FIX:
1. Replace Hard Drive controller and/or disk
2. Scan the database for data corruption caused by the failing controller