Kbase P17035: Database crashes with 290 error SYSTEM ERROR: I/O error in , ret file , addr . (290) when drive c
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   5/12/2009
Status: Verified

SYMPTOM(s):

Database crashes with 290 error SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290) when drive controller is faulty.

SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290)

SYSTEM ERROR: I/O error 0 in readfrmb, ret 0 file (srt), addr <n>. (290)

SYSTEM ERROR: I/O error 22 in readit, ret -1, file <n>, addr 0. (290)

Progress Client reading information in from a sort file is getting error 290 SYSTEM ERROR: I/O error <n> in <readit>, ret <n> file <n>, addr <n>. (290) when drive controller is faulty.

System log shows disk errors

FACT(s) (Environment):

UNIX
Progress/OpenEdge Product Family

CAUSE:

Not a Progress issue.
The problem can be caused by a disk or controller failure / error at the time a block is being read in the sort process.

FIX:

1. Replace Hard Drive controller and/or disk
2. Scan the database for data corruption caused by the failing controller