Kbase P14919: Error 752 when running rfutil -C aimage scan.
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  10/20/2003 |
|
Status: Unverified
FACT(s) (Environment):
Progress 8.x
FACT(s) (Environment):
Progress 9.x
SYMPTOM(s):
Error 752 when running rfutil -C aimage scan:
Invalid after image version number found in ai file header (752)
Last AIMAGE BEGIN Thu Jan 1 01:00:00 1970 (1640)
This file was last opened for output on Thu Jan 1 01:00:00 1970. (1643)
CAUSE:
When running aimage scan, the wrong ai file could be specified by mistake for the -a parameter.
If the ai file scanned is from another Progress version, then the 752 appears while the 1640 and 1643 messages nonetheless generally display the correct date and time.
If the ai file specified is also an unused ai file, then the 1640 and 1643 messages appear as in the symptoms above.
FIX:
Ensure that the scan is being done on the correct ai file.