Consultor Eletrônico



Kbase P13012: SYSTEM ERROR: Unable to extend database within area . (8897) due to HFSZLIM parameter
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   15/03/2010
Status: Verified

SYMPTOM(s):

Database goes down with 8897 error

SYSTEM ERROR: Unable to extend database within area <pareaName>. (8897)

SYSTEM ERROR: Unable to extend database within area Schema Area. (8897)

FACT(s) (Environment):

Caldera Open UNIX/SCO UnixWare
Progress 9.1C

CAUSE:

Due to kernel limit HFSZLIM parameter not being set to allow 2 GB extents.

FIX:

Increase HFSZLIM kernel parameter.

To display hard and soft limits for your system issue the following command:

$ idtune -g HFSZLIM

Sample output:

0x7FFFFFFF 0x3FFFFFFF 0x100000 0x7FFFFFFF

Values are listed in the following order (decimal equivalent for displayed values):

Current value of the tunable parameter (2,147,483,647)
Default value, from the Mtune entry (930,576,247)
Minimum valid value, from the Mtune entry (1,048,576)
Maximum valid value, from the Mtune entry (2,147,483,647)