Kbase P13012: SYSTEM ERROR: Unable to extend database within area . (8897) due to HFSZLIM parameter
Autor |
  Progress Software Corporation - Progress |
Acesso |
  Público |
Publicação |
  15/03/2010 |
|
Status: Verified
SYMPTOM(s):
Database goes down with 8897 error
SYSTEM ERROR: Unable to extend database within area <pareaName>. (8897)
SYSTEM ERROR: Unable to extend database within area Schema Area. (8897)
FACT(s) (Environment):
Caldera Open UNIX/SCO UnixWare
Progress 9.1C
CAUSE:
Due to kernel limit HFSZLIM parameter not being set to allow 2 GB extents.
FIX:
Increase HFSZLIM kernel parameter.
To display hard and soft limits for your system issue the following command:
$ idtune -g HFSZLIM
Sample output:
0x7FFFFFFF 0x3FFFFFFF 0x100000 0x7FFFFFFF
Values are listed in the following order (decimal equivalent for displayed values):
Current value of the tunable parameter (2,147,483,647)
Default value, from the Mtune entry (930,576,247)
Minimum valid value, from the Mtune entry (1,048,576)
Maximum valid value, from the Mtune entry (2,147,483,647)