Consultor Eletrônico



Kbase P12896: When running code that uses ActiveX proxies, the following error may occur. Runtime error 429 Acti
Autor   Progress Software Corporation - Progress
Acesso   Público
Publicação   02/01/2009
Status: Verified

SYMPTOM(s):

The visual basic scripts that reference temp tables fail, all others are working fine.

When running code that uses ActiveX proxies, the following error may occur.
Runtime error 429 ActiveX Component cannot create object

DLLRegisterServer in o4glactivex.dll failed.
Return code was: 0x80004005

O4glrt.zip is in the Classpath.

Proxies have been registered on this machine.

Windows is at service pack 2.

Progress is at patch level 26.

FACT(s) (Environment):

Windows 2000
Progress 9.1B

CHANGE:

Machine is a new setup and the VB scripts were moved from a different machine.

CAUSE:

Did not follow all the steps listed in the Open Client Developers Guide.
Specifically, did not register the o4glActiveX.dll.

FIX:

Register o4glActiveX.dll with Regsvr32.exe.